Customization: | Available |
---|---|
Certification: | ISO, CE |
Type: | Imaging System |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Voxel Size (mm):0.05 - 0.25
FOV (cm * cm):12 * 10,8 * 8,5 * 8
Software SmartV2&Cephro:Included
Including 1 set workstation & monitor:Included
Spatial Resolution :2.0 lp/mm
Reconstruction Time :< 60 s
Voxel Size :0.05 - 0.25 mm
Weight :220 kg(485.02 lb)
Features of Smart 3D-X 3-in-1 intelligent CBCT 3D Panorama Scan
Extraordinary Image
QuartZ4 scan platform, supporting flexible scan mode
Multiple focus layers in panoramic imaging, fitting the patients' dental arch
360° scan and 800 frame images with unique CT algorithms
Cephalometric PA/LAT and carpus shot for orthodontic treatment
User-friendly
Easy-to-target scan area
Seven positioning lasers with face-to-face communication to posit precisely
X-type base is convenient for wheelchair - bound patients
10" LED touch screen
Storage box design
Voice reminder
CBCT Photography
Multiple FOVs:
16cm × 10cm
15cm × 10cm
12cm × 10cm
8cm × 8cm
5cm × 8cm
High Resolution up to 2.0 lp/mm
Voxel Size 0.05-0.25 mm
Panoramic Image Reconstructed from
3D Image Data
Enhanced Image by Small Focal Spot
X-ray Tube
Three Scan Modes
DENTAL RADIOLOGY SOFTWARE
Implant Simulation
It can evaluate the bone quality and bone quantity of the implant area, automatically outline the neural tube. Clarifying the relationship between the implant position and the adjacent anatomical structure to accurately select the implant position, the optimal length and diameter of the implant. It can improve the success rate, and avoid possible nerve or blood vessel damage.
Multi - Planar Reconstruction (MPR)
In SmartVPro software, doctors can simultaneously view axial, coronal, and sagittal images. The software also allows for customized slice positioning, enabling buccolingual and mesiodistal cross - sections at any desired location. This feature enhances diagnostic convenience by providing comprehensive imaging perspectives.
Metal Artifact Correction
With the new T - MAR correction module for metal artifact removal, the system corrects metal artifacts intelligently. It avoids overmodification and saves the original clinical data.
Multiple Images
Support CT / PAN / CEPH.
Density Measurement
Visual assessment of bone quality, bringing greater convenience to dentists.
Image Slice for Implanting
It permits the evaluation of the overall osteogenesis and facilitates the macroscopic observation of the bone condition around implants.
ARTIFICIAL INTELLIGENCE
AI+Low Dose
Boosted by the deep learning-based CT reconstruction algorithm, the Smart3D-X can now obtain more defined tomography while further reducing the radiation dose, continuing to raise the industry standard for low-dose control.
AI+Automatic Head Position Correction
It enhances the accuracy and reliability of CT imaging, producing more precise lateral cephalometric images. It also ensures that scan results at different times can be compared and analyzed effectively.
AI+Nerve
This function can locate the shape of the inferior alveolar nerve in 3D space, as well as the positional relationship between the relative alveolar bone wall, adjacent teeth, and implants, providing a reference for doctors, greatly improving work efficiency and reducing surgical risks.
AI+Predict Bone Age by Observing the Cervical Spine
With bone age analysis, the patient's growth and development level and maturity can be accurately evaluated. It can provide reference for the diagnosis of oral diseases and the selection of orthodontic treatment solution.
Technical Specifications
Field of View | 16cm × 10cm,8cm × 8cm, 5cm × 8cm |
15cm × 10cm,8cm × 8cm,5cm × 8cm | 12cm × 10cm, 8cm × 8cm, 5cm × 8cm |
Detector Type | CsI+TFT | ||
Tube Voltage | CT/PAN/CEPH 60 - 100 kV | ||
Tube Current | CT/PAN/CEPH 2 - 10 mA | ||
Exposure Time | CT: 9.5 s / 12.5 s / 18.5 s | ||
PAN: 8.1 s / 18 s | |||
CEPH: 7.5 s / 10.1 s / 11.8 s | |||
Focal Spot Size | CT/PAN/CEPH 0.5 (IEC60336) | ||
Spatial Resolution | 2.0 lp/mm | ||
Reconstruction Time | < 60 s | ||
Voxel Size | 0.05 - 0.25 mm | ||
Weight | 220 kg(485.02 lb) |